Energy Management
Energy Management
Energy Management

item6Medium Voltage Active Voltage Conditioner

The Active Voltage conditioner (AVC) can be applied at Medium Voltage(MV) from 1kV up to 36kV with loads from 1 MVA to 50MVA.

It can be applied to a complete facility or to part of a facility network or to a specific critical MV load.

High efficiency >98% High power voltage conditioning

No Storage

  • No fault contribution
  • Able to correct for multiple sequential sags as there is no recharge time
  • No resonance with system capacitors
  • Does not saturate downstream distribution transformers

Continuous correction of:

  • 10% under-voltage—protection from utility voltage reductions
  • Voltage balance
  • Voltage flicker
  • Voltage harmonics - see details
  • 30 seconds (not cycles) correction of:
  • Up to 50% 3-phase voltage sags
  • Up to 83% 1-phase voltage sags

Other features:

  • Outdoor enclosure, for all environments 
  • Easy 3-wire in 3-wire out installation
  • Facility wide or load dedicated solutions.
  • It is usually more economical to focus on dedicated loads if total critical load to be protected is less than 80% of total plant load.

ArrowBluepixeldroptran1a1bExamples of how much you can save

ArrowBluepixeldroptran1a1Which solution is right for you? AVC Selection Guide

ArrowBluepixeldroptran1a2aBack to Omniverter AVC overview

 

Transmission Line Event @ 69kV seen at 26.4kV load

Transmission line fault reflected through 26.4 kV utility distribution system would have caused production stoppage with 1 phase down to 58% of nominal voltage. The Active Voltage Conditioner protected the facility providing output voltages > 96% so no production interruption occurred.
MV1

 

Distribution Line Event at 26.4 kV

A two phase sag on the utility distribution system caused two of the three phases to drop below 80% of nominal for 1 second which would have caused production in the facility to stop.

The AVC at 26.4 kV corrected Line to Line Voltages to nominal—no loads were dropped during voltage sag and production continued without any problem.
MV2

For more details on AVCs click here

Energy Management

InfoIiconProduct Information:
PDFiconsmtrans1a1a1aOminverter AVC Medium Voltage

item13a
sales@measurlogic.comitem4a2P: 1-877-PQ-SOLNS (877-777-6567)item4aF: 425-799-4780item4a1Measurlogic, Inc. 2007
item4a1a

EnergyManagement
Solutions
PowerQuality
VoltageSagSupport
instrumentation
quality
power
CurrentTransformers
Connectivity
Software
voltage
sag

ExclamationgraphicsmPower sags and brownouts create serious and costly production problems.

item3
26kV 2MVA AVC protects a high speed bottling plant

item8
Power sags and brownouts create serious and costly production problems.

Your Energy Management and Power Quality Partner

Measurlogic > Voltage Sag Support > Omniverter > Medium Voltage AVC

Omniverter Active Voltage Conditioners

ArrowBluepixeldroptran1a1a1Low Voltage

ArrowBluepixeldroptran1a2bMedium Voltage

ArrowBluepixeldroptran1a1cNot Sure?

AVCs1aAVCs2a

Downloadfolder1Downloads

homeicon1Home

Contactlittleguy1Contact Us

dboxes3colorsSite Map

MeasurlogicHome