DTS 310

$0.00

DIN rail Mount / Line Powered

  • Compact – 4.73” L x 1.38” W x 4.25” H
  • ANSI C12.20 – Revenue Grade
  • ETL Listed, CE, FCC, BTL Listed, SunSpec Alliance certified
  • 208-480Vac, L-L (1P 2W, 1P 3W, 3P 4W)
  • 600Vac, L-L, 3 or 4 W (option)
  • Ethernet, RS-485 and/or Pulse (kWh) connectivity
  • Modbus TCP, BACnet/IP, SNMP or DNP 3.0
  • Modbus RTU, BACnet MS/TP or LonWorks
  • 333mV, 5A or Rope CT inputs
  • Digital Input/Outputs, Low Voltage Auxiliary, DTS Logging System options
  • Bi-directional for renewable systems (NET metering)
  • Specifications above are model dependent.

Product Description

One of the most versatile and accurate meters on the market. The DTS 310 has a very compact DIN rail design, requires no external power source to operate, and comes with color coded, pluggable connectivity. This meter is certified to ANSI C12.20 Class 0.2 (Revenue Grade) providing the most accurate data acquisition available. It can function in either a single, split or three phase environment and is equipped with auto-topology detection. The DTS 310 works with all “safe” 333mV or 5A current transformers (CTs) and comes with CT Reverse Algorithms for automatic correction of in-proper field mounted CTs.

For easy configuration in-the-field, communications can be set via DIP switches when utilizing the Modbus RTU protocol. Or for remote configurability, all the DTS Series of meters are offered with our free DTS Config software platform; where you can conveniently choose from over 200 parameters at the frequency you require. It also has a User-definable Modbus register area.

The DTS 310 is available with optional digital status/counter inputs or digital outputs, which can be used to import gas or water meters or to control any third party device; and is offered with optional on-board logging with our DTS Logging System. Also, if in the future, you decide to integrate renewable energy sources, the DTS 310 will conveniently operate as a Bi-directional NET meter. The DTS 310 is SunSpec Alliance certified and easily integrates with Building Automation Systems and Energy Monitoring Software. All our DTS Series of meters are designed and manufactured in the USA and comply with the Buy American Provisions of ARRA Section 1605.

 

Features

  • Line powered single / three phase energy submeter
  • Auto-topology detection
  • Compact DIN rail design: 4.73” L x 1.38” W x 4.25” H
  • ETL Listed, BTL Listed, SunSpec Alliance certified
  • ANSI C12.20 – “Revenue grade”
  • 208-600Vac, L-L (CAT III) or 120-347Vac L-N (CAT III)
  • Ethernet connectivity – Modbus/TCP, BACnet/IP, SNMP or DNP 3.0
  • RS-485 connectivity – Modbus RTU or BACnet MS/TP – and/or Pulse (kWh) connectivity
  • LonWorks FT-10 communications
  • Communications setting via DIP switches for Modbus RTU
  • Interfaces with “safe” 333mV, 5A or RopeCTs
  • Bi-directional for renewable systems (NET metering)
  • 2 digital status/counter inputs OR digital outputs – optional
  • 12-24Vdc or 24Vac auxiliary power supply input
  • 48Vdc auxiliary power supply input
  • Color coded, pluggable connectivity
  • User configurable using DTS Config software
  • User-definable Modbus register area
  • Designed and Manufactured in the USA.
  • Complies with Buy American Provisions of ARRA Section 1605

Specifications

Measuring Circuits

Voltage range: 208-600Vac, L-L (CAT III)
120-347Vac L-N (CAT III)
Voltage overload: 1.1 x
Voltage burden: <0.1 VA @ 277 Vac L-N
Frequency: 45 to 65 Hz
Rated current: 333mV, 5A or model dependent
Current overload: 1.2 x
Power overload: 1.2 x

Accuracy

Voltage: 0.5%, <0.2% typical (80-120%)
Current: 0.5%, <0.2% typical (10-120%)
Power: 0.5%, <0.2% typical (10-120%)
Power Factor: 0.5% (between 0.5 and 1.0)
Energy:** Class 0.2 (ANSI C12.20)

Voltage Supply (Self Powered)

Voltage: Powered from Phase A & B or Phase A & Neutral (model dependent)
Frequency: 50/60 Hz
Burden: <2VA

Low Voltage Auxiliary (Option)

Voltage Options: 12-24Vdc or 24Vac
Tolerance: +/- 10%
Burden: <2VA
Isolation: Must be powered from a Class 2
IEC 60950 isolated power supply

Isolated DC Auxiliary (Option)

Voltage Options: 12 or 24 or 48 Vdc
Tolerance: -25%, +50%
Burden: <3VA
Isolation: 1500Vdc

Mechanical

Connection: Pluggable screw terminals suitable for 12AWG stranded wire (2.5mm2)
Case Material: Self-extinguishable, V0 plastic
Protection: Nema 1 (IP40)
Dimensions: 4.73”(120mm) D x 4.25”(108mm) H x 1.38”(35mm) W
Weight: 1lb (0.45 kg)

Environmental:

Operating temp: -4º to 158ºF (-20º to 70ºC)
Storage temp: -40º to 185ºF (-40º to 85ºC)
Humidity: 5 to 95% R.H. non-condensing

Communications (Serial)

Connection: 3 way pluggable, screw terminal
Protocols: Modbus RTU (SunSpec Certified) or BACnet MS/TP (BACnet Listed)

Communications (LonWorks)

Connection: 2 way pluggable, screw terminal
Protocols: LonWorks FT-10

Communications (Ethernet)

Connection: RJ45, 10/100Base-T
Protocols: Modbus TCP (SunSpec Certified), BACnet/IP (BACnet Listed), SNMP or DNP 3.0 over IP

Pulse / Status Outputs (Option)

Type: Potential Free, N.O. Solid State Relay
Pulse Width: Max 10 Pulses per Second
Pulse Rate: 1 Pulse / 1 KWh default, user configurable
Max On-Resistance: 30 ohm
Max switching voltage: 50Vdc or 30Vac
Max switching current: 120mA (350mA for 10mS)
Connection: Isolated Pin-Pair (Output 3, Outputs 1 and/or 2)

Connection

Counter / Status Inputs: – Optional
Type: Dry Contact
Min Pulse Width: 50mS, Max 10 Pulses per Second
Max Current/Voltage: 15mA / 6V
Connection: 2 Pin-Pairs (Inputs 1 and/or 2)

Standards & Safety

ETL listing: 4001073
Conforms to: UL Std 61010.1
Certified to: CSA Std C22.2 # 61010.1
EMC:
IEC 61000-6-3 Emmissions, IEC 61000-6-2 Immunity,
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8,
IEC 61000-4-11
Emissions: CISPR 22 / FCC Part 15 Class A
Other: Measurement Category III

Data Sheets & Downloads

Brochures

DTS 310 Brochure (1.9 Mb) [PDF]
Right Angle Bracket Datasheet (1.3 Mb) [PDF]
Inline Fuse Kit Sheet (1 Mb) [PDF]

Technical

DTS 310 – Installation Guide (3 Mb) [PDF]

Software

DOWNLOAD DTS CONFIG — Current Version 1_40_0_229 (1.6 Mb) [ZIP]
Download DTS Toolbox — Current Version 1.01aA (9.2 Mb) [ZIP]

DTS Modbus Map (456.4 Kb) [PDF]
DTS Modbus Addendum (SunSpec) (215.4 Kb) [PDF]
DTS BACnet MS/TP Map (369 Kb) [PDF]
DTS BACnet/IP Map (182.2 Kb) [PDF]
DTS LonWorks Map (150 Kb) [PDF]
DTS SNMP Map (146.1 Kb) [PDF]
DTS DNP 3.0 Map (157.1 Kb) [PDF]

DTS Logging System (308 Kb) [PDF]
Configuring digital outputs (700.4 Kb) [PDF]

You may also like…