MLG-HE4 Series
Split Core Hall Effect Sensors
- Split core for easy measurement of existing systems
- 500A, 800A and 1000A models available
- 1.57” (40mm) aperture allows for large diameter current conductors
- Uni-directional and bi-directional current models
- Pluggable screw terminals
- Panel mountable
- +-15Vdc supply
- 4-20mA output
- Open loop current sensor
- 1% accuracy
- See MLG-HE2 Series for currents between 50A and 200A
Product Description
MLG-HE4 split core Hall Effect sensors are ideal for use in DC current applications from 500A up to 1000A. For smaller currents from 50A up to 200A see our MLG-HE2 Series
The MLG-HE4 hall-effect sensor has a 4-20mA output. It is offered with uni-directional or bi-directional current measuring configurations. They are powered from + and – 15Vdc supplies. Measurlogic offered a 24Vac input, + and – 15Vdc output din rail mounting power supply module that is capable of powering up to 3 x MLG-HEx hall-effect sensors. If paired with our 1500Vdc DTS DC3 sub-meter the hall-effect power supplies are built into the DTS DC3 meter for simpler integration.
Features
Split-core Design/Built-in Mounting Brackets
- Makes installation a snap
Uni-directional OR Bi-directional 4-20mA Output
- Ideal for measuring loads that have current flow in one OR both directions
Panel mounting mounting
- Flexible mounting alternatives
Specifications
Output Signal | 4 – 20mA – uni-directional measurement |
Linearity | < 1% |
Frequency Range | DC |
Power Supply | + and – 15Vdc |
Power Consumption | 35mA maximum |
Current Ranges | 500A, 800A and 1000A |
Sensing Aperture | 1.57” (40mm) diameter |
Environmental | -10 to 85 degrees Celsius |